Autoclave - professional, chamber device designed for disinfection
Professional autoclave for disinfecting documents, banknotes, and items. Utilizes UV-C light, ozone, and hot air to eliminate 99.9% of microorganisms, including COVID-19 virus. Features LCD display, voice communicator, and safety lock. Watch our Doxon UV-C box visualization video.
The rules are described in detail in the GDPR tab.
Min. 140 PLN free delivery. DPD courier, InPost parcel lockers.
"You have the right to return the goods. Details are described in the regulations."
Autoclave - a professional, chamber device designed for disinfecting documents, correspondence, invoices, books, banknotes, coins, as well as items deposited (keys, jewelry, watches, etc).
Characteristics of the DOXOZON UV-C document disinfection device:
• Type B and C ultraviolet light, ozone generator, hot air at temperatures up to 70 degrees Celsius
• Load capacity - up to 15 kg
• Energy efficiency
• Durable steel housing
• LCD display, voice communicator emitting information about the device status and disinfection progress
• Safety and ease of use
How does the autoclave work?
You place the documents in the chamber, trying to ensure that the paper is evenly distributed inside the autoclave chamber.
From the device MENU displayed on the screen, you select one of the operating modes:
1 # correspondence, envelopes, loose papers
2 # document folders
3 # books
4 # coins and banknotes
5 # watches, jewelry, deposit
6 # electronics
What is the elimination of microorganisms based on?
The autoclave uses up to 3 active methods to eliminate viruses, bacteria, and fungi. By combining them, the device's effectiveness reaches 99.9% - including the elimination of the COVID-19 virus
* Phase 1: Intensive ozone circulation
* Phases 2 and 3: Ozone treatment until the maximum possible ozone concentration is achieved inside the chamber, along with UVB and UVC irradiation
* Phase 4: Infrared and thermal radiation until the temperature of the items reaches 70 degrees Celsius
* Phase 5: Active ozone neutralization
* Phase 6: Cooling the interior
Thanks to the automatic lock, it is not possible to open the autoclave chamber during the process, especially when the radiator temperature exceeds 55 degrees or when the ozone has not been neutralized inside
The process time averages from 30 to 80 minutes (depending on the selected program and load quantity)
Operation is facilitated by voice messages (in Polish) from the speaker. Parameters: Ozone quantity, ozone unit temperature, radiator temperature, housing temperature, time until the end of the process - are constantly displayed on the color LCD screen.
Technical parameters:
external
width: 42 cm
length: 61.5 cm
height: 27.5 cm
internal:
width: 39 cm
length: 49 cm
Watch a video presenting the visualization of our Doxon UV-C box: